Statio Onus Electricae Autocinetorum Integrata, Efficax Impetus, 240KW-400KW DC, Statio Onus Electricae EV, Gradus 3, IP54, Impermeabilis

Descriptio Brevis:

• Sustentatio V2G/V2L/V2H

• Impletio Parallela

• Configurationes potentiae emissae configurabiles

• Lector RFID

• Lector Chartarum Creditarum (vel fortasse: Lector Chartarum Creditarum)

• OCPP 1.6J congruens

• Diagnostica FRU in Tabula

• Facile conservatur


  • Conectores:CCS1 || CCS2 || CHAdeMO || GBT || NACS
  • Tensio Ingressa:400VCA / 480VCA (3P+N+PE)
  • Tensio Egressus:200 - 1000VDC (Potentia constans: 300 - 1000VDC)
  • Currens egressus (aere refrigeratus):CCS1- 200A || CCS2 - 200A || CHAdeMO – 150A || GBT- 250A|| NACS - 200A
  • Currens egressus (liquido refrigeratus):CCS2 – 500A || GBT- 800A || GBT- 600A || GBT- 400A
  • Potentia aestimata:240-400kW
  • Protectio Ingressus:IP54 || IK10
  • Longitudo funis onerandi: 5m
  • Dimensiones (L × P × A):900mm × 700mm × 1900mm
  • Detalia Producti

    Etiquettae Productarum

    Haec seriesPali onerandi DCDesigno robusto gloriatur et usque ad 320kW augeri potest.Acervus onerandi currus electrici DC refrigeratus liquido(400 kW). Pali oneratorii celeres onerationis praebent et onerationem duorum sclopetorum sustinent, quae celerem onerationem vehiculis magnae potentiae et magnae capacitatis accumulatoris permittunt. Productum systemate moderationis provecto et modulo communicationis instructum est, functiones sicut ordinationem intelligentem, monitorium remotum, et diagnosim errorum sustinens. Conexionem cum praecipuis suggestis administrationis pali oneratorii sustinet. Per conexionem cum suggestu nubili, operatores statum operationis pali oneratorii in tempore reali monitorare et sustentationem atque emendationes remotas perficere possunt.

    Caricator vehiculorum electricorum seriei DC 240-400kW

    Categoria specificationes Data parametri
    Structura speciei Dimensiones (L × P × A) 900mm × 700mm × 1900mm
    Pondus Quadringenta chiliogrammata
    Longitudo funis onerandi 5m
    Conectores CCS1 || CCS2 || CHAdeMO || GBT || NACS
     

     

     

    Indicatores electrici

    Tensio Ingressa 400VCA / 480VCA (3P+N+PE)
    Frequentia ingressus 50/60Hz
    Tensio Egressus / Currens Egressus (Aere Refrigeratus) 200 - 1000VDC (Potentia constans: 300 - 1000VDC) CCS1– 200A || CCS2 – 200A || CHAdeMO150A || GBT- 250A || NACS – 200A
    Currens egressus (liquido refrigeratus) CCS2 – 500A || GBT- 800A || GBT- 600A || GBT- 400A
    potentia aestimata 240-400kW
    Efficacia ≥94% ad potentiam nominalem emissam
    Factor potentiae 0.98
    Protocollum communicationis OCPP 1.6J
    Designatio functionalis

     

     

    Systema RFID monstrandi LCD 7'' cum tactili velamento ISO/IEC 14443A/B
    Imperium Aditus RFID: ISO/IEC 14443A/B || Lector Chartarum Crediticiarum (Optionalis)
    Communicatio Aethernet – Ordinarium || 3G/4G || Wifi
    Refrigeratio Electronicae Potestatis Aere Refrigeratum || Liquore Refrigeratum
    Ambitus laboris

     

     

    Temperatura operandi -30°C ad55°C
    Operans || Humiditas Reponendi ≤ 95% RH || ≤ 99% RH (Non condensans)
    Altitudo < 2000m
    Protectio Ingressus IP54 || IK10
    Designatio securitatis Norma salutis GB/T, CCS2, CCS1, CHAdeMo, NACS
    praesidium salutis Praesidium contra supertensionem, praesidium contra fulgur, praesidium contra supercurrentem, praesidium contra effluxum, praesidium contra aquas impervias, etc.
    Sistio Emergentiae Globulus Sistendi Emergentiae Potestatem Productionis Intercludit

    Contacta nosUt plura de statione onerandi vehiculorum electricorum refrigeratione liquida BeiHai 240KW-400KW discas.


  • Praecedens:
  • Deinde:

  • Nuntium tuum hic scribe et nobis mitte.